Consulting, design and measurement of loudspeaker systems according to DIN VDE 0833-4 and DIN EN 50849
For many public buildings, voice alarm systems in accordance with DIN VDE 0833-4 or DIN EN 50849 are mandatory. We design such systems by computer predictions to confirm that the required speech intelligibility can be provided even before the building is completed. We also assist in designing any necessary room acoustic treatment and undertake the commissioning, optimisation and programming of voice alarm systems on site–anyhwere in the world. For measurements according to DIN EN 60268-16:2012-05 we are accredited according to DIN EN ISO/IEC 17025:2018, Jakob Kraft is “responsible person for voice alarm systems” according to DIN 14675 -1.
In Berlin, Potsdam and Brandenburg we also supply turnkey sound reinforcement systems for churches, conference and seminar rooms and much more.
Design Services
- Voice alarm systems for airports, train stations and more according to ISO 7240-19 / NFPA 72
- Emergency Sound Systems according to EN 50849
- Generation of specifications and tender documents
- Measurement and analysis of existing systems
- New planning for projects of any size
- Prediction of speech intelligibility according to DIN EN 60268-16
- Certificates according to ISO 7240-19, DIN VDE 0833-4, DIN EN 50849, VDE 0828-15
- Commissioning & Programming & Verification Measurements
- Expert reports
Our Projects
- Customer: Peter Grundmann ArchitectsCentre for Art and UrbanismNoise immission forecast
- Criminal Court BerlinRoom and electroacoustic inventory with subsequent planning
- Groundwater purification plantDetermination of the sound immissions
- IMD Labor Oderland GmbHFrom bank building to laboratorySound immission prediction and room acoustics consulting
- Customer: Planungswerk Näther WuckeHavel School OranienburgRoom acoustics consulting
- Axica Conference CentreRoom acoustic investigation to improve speech intelligibility
- Märkisches Zentrum BerlinNoise immission forecast
- Customer: Alte Feuerwache e.V.Old fire stationPlanning sound system
- Residential and commercial quarter Liebermannstr.Determination of the sound immissions
- Customer: Spandau District OfficeJonny K. Active ParkNoise immission forecast
- Sports hall of the Ev.Schule Berlin LichtenbergRoom acoustics consulting
- Relocation of a venueHeideglühenConsultation and levelling of a sound system
- Customer: STRABAG Real Estate GmbHCity HallVillas SchönefeldBuilding acoustics - sound insulation
- Customer: Vivantes GmbHListening booths Vivantes HospitalMeasurement of room acoustics
- Noise immissions from water trafficChancellor's OfficeBuilding acoustics - sound insulation
- Customer: Treptow-Köpenick District Office of BerlinKöpenick Town HallConstruction noise
- Friedrichshain District CentreDetermination of the sound immissions
- Berlin CathedralFestival of LightsLeveling of sound reinforcement systems
- Measurement of the standard impact sound levelRedevelopment office buildingBuilding acoustics - sound insulation