Consulting, design and measurement of loudspeaker systems according to DIN VDE 0833-4 and DIN EN 50849
For many public buildings, voice alarm systems in accordance with DIN VDE 0833-4 or DIN EN 50849 are mandatory. We design such systems by computer predictions to confirm that the required speech intelligibility can be provided even before the building is completed. We also assist in designing any necessary room acoustic treatment and undertake the commissioning, optimisation and programming of voice alarm systems on site–anyhwere in the world. For measurements according to DIN EN 60268-16:2012-05 we are accredited according to DIN EN ISO/IEC 17025:2018, Jakob Kraft is “responsible person for voice alarm systems” according to DIN 14675 -1.



Design Services
- Voice alarm systems for airports, train stations and more according to ISO 7240-19 / NFPA 72
- Emergency Sound Systems according to EN 50849
- Generation of specifications and tender documents
- Measurement and analysis of existing systems
- New planning for projects of any size
- Prediction of speech intelligibility according to DIN EN 60268-16
- Certificates according to ISO 7240-19, DIN VDE 0833-4, DIN EN 50849, VDE 0828-15
- Commissioning & Programming & Verification Measurements
- Expert reports
Our Projects
Projects: Type
Show all
Highlights
Public transportation
Culture & Sports
Industrial
Residential & Hotels
Events & Gastronomy
Public Buildings
Sacral Buildings
Education & Health Services
Office & Conference
Projects: Service
Show all
Building Acoustics
Sound Systems & Voice Alarm
Environmental Noise
Room Acoustics
Building physics & sustainability
Customer: Peter Grundmann ArchitectsCentre for Art and UrbanismNoise immission forecast
Criminal Court BerlinRoom and electroacoustic inventory with subsequent planning
Groundwater purification plantDetermination of the sound immissions
IMD Labor Oderland GmbHFrom bank building to laboratorySound immission prediction and room acoustics consulting
Customer: Planungswerk Näther WuckeHavel School OranienburgRoom acoustics consulting
Axica Conference CentreRoom acoustic investigation to improve speech intelligibility
Märkisches Zentrum BerlinNoise immission forecast
Customer: Alte Feuerwache e.V.Old fire stationPlanning sound system
Residential and commercial quarter Liebermannstr.Determination of the sound immissions
Customer: Spandau District OfficeJonny K. Active ParkNoise immission forecast
Sports hall of the Ev.Schule Berlin LichtenbergRoom acoustics consulting
Relocation of a venueHeideglühenConsultation and levelling of a sound system
Customer: STRABAG Real Estate GmbHCity HallVillas SchönefeldBuilding acoustics - sound insulation
Customer: Vivantes GmbHListening booths Vivantes HospitalMeasurement of room acoustics
Noise immissions from water trafficChancellor's OfficeBuilding acoustics - sound insulation
Customer: Treptow-Köpenick District Office of BerlinKöpenick Town HallConstruction noise
Friedrichshain District CentreDetermination of the sound immissions
Berlin CathedralFestival of LightsLeveling of sound reinforcement systems
Measurement of the standard impact sound levelRedevelopment office buildingBuilding acoustics - sound insulation

